1. Low weight, small volumn
2. low cost, low price
3. Good accuracy: 0.5%
4. Is a type of digit flowmeter, also called electronic water flowmeter
5. can be installed vertically or horizontally
6. can be work at high pressure 10MPa
7. connection method: ferrule (snap-on), flange, threaded
1. Operating Principle:
Â
Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.
Â
Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact U-IDEAL.
Â
Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized product's specification.
2. Technical DataÂ
ÂMeasuring system Â
Application range  |
Liquid: water; diesel; gasoline
|
Measured Value | Â |
Primary measured value  | Flow Rate |
Secondary measured value  | Volume flow  |
Design Â
Features  |  |
Modular construction  | The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version.  |
Compact version converter    |
N Type: Pulse output without local display |
A Type: 4-20mA Output without local display | |
B Type: Local Display; Lithium Battery Power; Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â No Output | |
C Type: Local Display; 24V DC Power; 4-20mA Output; Â Optional Function: Â
| |
Connection   |
Thread: DN4-DN50 |
Flange: DN15-DN200 (DIN, ANSI, JIS) | |
Wafer: DN15-DN100 | |
Measurement Ratio | Standard - 10:1; Optional: 20:1 |
Â
Measuring accuracy Â
Reference conditions  | Flow conditions similar to EN 29104  |
Medium: Water  | |
Electrical conductivity: ≥ 300 μS/cm  | |
Temperature: +10...+30°C / +50...+86°F  | |
Inlet section: ≥ 10 DN  | |
Operating pressure: 1 bar / 14.5 psig  | |
Flow Meter Accuracy  |
Standard: 1.0% of rate |
Optional:Â 0.5% of rate |
Operating conditions Â
Temperature | Â |
Process temperature  | T1 Level: -20...+80°C  |
T2 Level: -20...+120°C  | |
T3 Level: -20...+150°C  | |
Ambient temperature  (all versions)  |
Standard (with aluminum converter housing):  |
-10…+55°C  | |
Storage temperature  | -20...+70° |
Pressure | Â |
 EN 1092-1  | DN100…DN200: PN 16  |
DN15…DN80: PN 25 | |
Other pressures on request  | |
ASME B16.5 Â | 1/2"...8": 150 lb RF Â |
Other pressures on request  | |
JIS Â | 1/2"...8": 10 K Â |
Other pressures on request  |
Installation conditions Â
Installation   |
Take care that flow sensor is always fully filled  |
For detailed information see chapter "Cautions for Installation" Â | |
Flow direction   |
Forward |
Arrow on flow sensor indicates flow direction. Â | |
Inlet run  | ≥ 10 DN  |
Outlet run  | ≥ 5 DN  |
Materials Â
Sensor housing  | SS304 |  |
Other materials on request  |  | |
Flanges   |
SS304 | Â |
Other materials on request  |  | |
Rotor |  |  |
Standard: 2Cr13 | EN10088-3 Â Â Â Â Â Â 1.4021 | X20Cr13 |
AISI 420 | Â | |
BS 420S37 | Â | |
JIS SUS410J1 | Â | |
Optional: CD4MCu | DN15…DN80 |  |
Bearings and Shaft | Tungsten Carbide | Â |
Converter Housing | Standard: polyurethane coated die-cast aluminum  |
Process connections
Flange | Â |
EN 1092-1 Â | DN15...200 in PN 6...40 Â |
ASME  | 1/2"…8" in 150 lb RF  |
JIS  | 1/2"…8" in 10...20K  |
Design of gasket surface  | RF  |
 | Other sizes or pressure ratings on request  |
Thread | DN4…DN50 in PN63 |
Measurable Flow Rate Range: Â
Note: The flow range as blow is for reference only. Consult the factory if you have special requirement. Refer to the nameplate or certificate for actual flow range.
Â
Nominal Diameter | Standard Flow Range  | Extended Flow Range  | |
(mm) | (in.) | (m3/h) | (m3/h) Â |
4 | 0.15 | 0.04 to 0.25 | 0.04 to 0.4 |
6 | 0.25 | 0.1 to 0.6 | 0.06 to 0.6 |
10 | 0.4 | 0.2 to 1.2 | 0.15 to 1.5 |
15 | 0.5 | 0.6 to 6 | 0.4 to 8 |
20 | 0.75 | 0.8 to 8 | 0.45 to 9 |
25 | 1 | 1 to 10 | 0.5 to 10 |
32 | 1.25 | 1.5 to 15 | 0.8 to 15 |
40 | 1.5 | 2 to 20 | 1 to 20 |
50 | 2 | 4 to 40 | 2 to 40 |
65 | 2.5 | 7 to 70 | 4 to 70 |
80 | 3 | 10 to 100 | 5 to 100 |
100 | 4 | 20 to 200 | 10 to 200 |
125 | 5 | 25 to 250 | 13 to 250 |
150 | 6 | 30 to 300 | 15 to 300 |
200 | 8 | 80 to 800 | 40 to 800 |
3. Model and SelectionÂ
Model Selection (See Table 1)Â
Table 1: Model Selection Guidance for Liquid Turbine Flowmeter
Model Suffix Code |  |  |  | Description | ||||||
LWGY- | Â | Â | Â | Â | Â | Â | Â | Â | Â | |
Diameter |  |  |  |  |  |  |  |  |
Three Digitals; for example: 010: 10 mm;              015: 15 mm; 080: 80 mm;              100: 100 mm                |
|
Converter | N | No display; 24V DC; Pulse Output | ||||||||
A | No display; 24V DC; 4-20mA Output | |||||||||
B | Local display; Lithium Battery Power; No output | |||||||||
C |
Local display; 24V DC Power; 4-20mA Output; Â Optional backup power: Lithium Battery |
|||||||||
C1 |
Local display; 24V DC Power; 4-20mA Output; Modbus RS485 Communication Optional backup power: Lithium Battery |
|||||||||
H |
Local display; 24V DC Power; Â 4-wire 4-20mA Output & HART Communication |
|||||||||
Accuracy | ||||||||||
05 | 0.5% of Rate | |||||||||
Flow Range | S | Standard Range: refer to flow range table | ||||||||
W | Wide Range: refer to flow range table | |||||||||
Body Material | S | SS304 | ||||||||
L | SS316 | |||||||||
Explosion Rating | N | Safety Field without Explosion | ||||||||
E | ExdIIBT6 | |||||||||
Pressuring Rating | Â | N | Standard | |||||||
H(x) | Customized Pressure Rating | |||||||||
Connection | Â | Â | -DXX |
DXX: D06, D10, D16, D25, D40 D06: DIN PN6; D10: DIN PN10 D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 |
||||||
-AX |
AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600# |
|||||||||
-JX |
JX: J1, J2, J4 J1: JIS 10K; J2: JIS 20K; J4: JIS 40K |
|||||||||
-TH | Thread; DN4…DN50 | |||||||||
Fluid Temperature |  |  |  | -T1 | -20...+80°C | |||||
-T2 | -20...+120°C | |||||||||
-T3 | -20...+150°C |
Explanation - Diameter: 50mm; Converter: 24V DC Power Supply, 4-20mA Output, Local Display
Accuracy: 1.0%; Flow range: 4-40 m3/h; Body Material: SS304; No Explosion; Connection: ANSI 150# Flange; Fluid Temperature: -20…+80°C



A Derrick Crane is docking equipment installed on vessels or dockside. Derrick crane consists of derrick and hoisting mechanism. There are 3 or 4 steel wires connecting the derrick and hoisting mechanism, which controls hoisting mast goes up and down. A separate steel wire sling runs under the hoisting mast with a hook as the hoisting mechanism.
Features of Weihua Derrick Crane:
1. There are 4 driving system for the hoisting mechanism, 2 driving system for luffing mechanism.
2. The whole derrick crane chassis adopt basin support on concrete foundation, which can effectively ease the horizontal and vertical deformation of the derrick crane.
3. Multi-layer winding line reel drum. Hoisting winding drum wrapped with 4 layers of wire rope, and luffing drum is wrapped with 5 layers of wire rope.
4. Complete frequency control, half load lifting speed is 2 times faster than the full load lifting speed.
5. Inverter, encoder and electronic control system to ensure the 4 hoisting motors keep synchronous working.
Weihua provide professional lifting equipment solutions, customized cranes, Crane Components, installation, after sale service. Weihua products export to 110 countries such as Russia, Thailand, Malaysia, Egypt, Saudi Arabia, Parkistan, the Philippines, Mexico, etc. We have confidence to provide you with the professional solutions and right products. Our success comes from customers' success. Welcome to visit Weihua.
Derrick Crane
Derrick Crane,Fixed Derrick Crane,Fixed Dock Crane,Self-Climb Crane
Henan Weihua Heavy Machinery Co., Ltd. , https://www.weihuacranefactory.com